About Curtiss-Wright Round Rock

Curtiss-Wright Round Rock designs and manufactures temperature sensors, pressure transmitters and fiber-optic signal products in Round Rock, Texas, for aerospace, nuclear power and industrial customers. Founded in 1968 as Weed Instrument Co., the business became Ultra Electronics Nuclear Sensors & Process Instrumentation (NSPI) after a 2008 acquisition and joined Curtiss-Wright Corporation on December 31, 2024, as part of its Nuclear Division.

What Curtiss-Wright Round Rock makes

Aerospace temperature sensing. Round Rock winds its own platinum and nickel RTD elements, which lets it produce non-standard resistance curves. Those elements go into rugged immersion probes, surface sensors, air temperature sensors and Ultra-Cryo cryogenic sensors that monitor bleed air, cabin air, engine oil, fuel, hydraulic fluid and compressor discharge on commercial and military aircraft and reusable launch vehicles.

Nuclear-qualified temperature and pressure. RTDs, thermocouples and transmitters are qualified to IEEE 323 and IEEE 344 for Class 1E service across PWR, BWR, CANDU and other reactor types, including small modular reactors. The company reports that its temperature sensors are used for reactor coolant monitoring in more than 80% of US reactors, and its pressure transmitters in more than 20% of US plants. The DTC3 and DTN2070 transmitters give plants replacement paths for obsolete Rosemount and Foxboro instruments.

Fiber-optic products. Nuclear-qualified analog converters such as the N9487 and N9488 isolate safety and non-safety signals, while EOTec 2000 Ethernet switches and MX multiplexers carry industrial data across wide temperature ranges and in hazardous areas.

Why engineers specify Curtiss-Wright Round Rock

  • Qualification depth. Quality programs include AS9100D, ISO 9001:2015, ASME NQA-1:2015, ISO 19443 and CSA N299, backed by LOCA testing and RCC-E qualification for European designs.
  • Aerospace credentials. Round Rock is an FAA PMA supplier of aerospace temperature sensors.
  • Obsolescence solutions. Engineer-to-order designs, commercial grade dedication and equipment qualification services support plant life extension.
  • Accredited calibration. An A2LA-accredited ISO/IEC 17025 laboratory calibrates RTDs and thermocouples.

Local support from Vaughn Associates

The Southeast is home to Huntsville’s aerospace, missile and space programs, commercial nuclear plants in several states and Gulf Coast process facilities. Vaughn Associates helps engineers in each of these communities define sensor type, element, curve, qualification and documentation requirements before a quote is requested.

We coordinate quotes and technical questions with the Round Rock factory and follow each order through delivery. Vaughn covers Curtiss-Wright Round Rock in all of its territories.

Request application help, explore temperature sensors and RTDs and pressure transducers, or find your local rep.

In-house wound platinum and nickel RTD elements with non-standard curves

Instrumentation qualified to IEEE 323 and IEEE 344 for Class 1E nuclear service

FAA PMA supplier of aerospace temperature sensors

Drop-in replacements for obsolete nuclear pressure transmitters

A2LA-accredited RTD and thermocouple calibration

Product lines

What Curtiss-Wright makes — product categories we can help you specify.

01

Aerospace and space temperature sensors

Rugged fluid immersion, surface, air and cryogenic temperature sensors for commercial and military aircraft and reusable launch vehicles, including FAA PMA parts.

  • Ultra-Cryo
  • Accu-Sense

02

Wire-wound RTD elements

Precision-wound platinum and nickel sensing elements produced in-house, allowing non-standard resistance curves and values.

03

Aerospace pressure transducers

Strain-gauge pressure transducers with analog output for aerospace fluid and air systems.

04

Nuclear-qualified RTDs and thermocouples

Thermowell, surface, fast-response, direct-immersion and flexible spring-loaded sensors qualified to IEEE 323 and IEEE 344 for Class 1E nuclear service.

  • N9001
  • N9002
  • N9004
  • N9007
  • N9017
  • N9018
  • N9019
  • N9339
  • N9356

05

RCC-E qualified sensors

Temperature sensors qualified to the French RCC-E code for European and EDF-design reactors.

  • KN201
  • KN606
  • KN612
  • KN9004
  • KN9017

06

Nuclear pressure transmitters

Class 1E and non-safety pressure transmitters, including fully analog drop-in replacements for obsolete Rosemount and Foxboro designs.

  • DTN2070
  • DTC3
  • N-E11
  • N-E13
  • N-DR800

07

Extreme-environment pressure transducers

Pressure transducers for temperatures to 650 °F with remote electronics up to 250 ft away, immunity to magnetic fields and an integral temperature sensor.

  • NP9000

08

Temperature transmitters

Nuclear-qualified analog RTD and thermocouple transmitters, plus HART head-mount and DIN-rail transmitters qualified to IEEE 344.

  • N7030
  • N7040
  • 4500H
  • 7600H
  • 9100H
  • 7600D

09

Nuclear-qualified fiber-optic converters

Analog and contact-closure fiber-optic transmitters and receivers that provide electrical isolation between safety-related and non-safety systems.

  • N9487
  • N9488
  • N9288
  • FOT-CC
  • FOR-CC

10

Industrial fiber-optic networking

Ethernet switches, media converters, multiplexers and self-healing rings for analog, contact and serial signals, rated for –40 to +85 °C with Class I Div 2 and ATEX options.

  • EOTec 2000
  • MX multiplexers
  • 2C30

Applications

  • Bleed air and cabin air temperature
  • Engine oil, fuel and hydraulic system temperature
  • Compressor discharge temperature
  • Cryogenic temperature on launch vehicles
  • Reactor coolant system loop temperature
  • Pressurizer and feedwater pressure
  • Containment and HVAC monitoring
  • Replacement of obsolete nuclear transmitters
  • Safety and non-safety signal isolation
  • Fiber-optic SCADA links for utilities and tank farms

Standards & certifications

  • AS9100D
  • ISO 9001:2015
  • ASME NQA-1:2015
  • ISO 19443
  • CSA N299
  • ISO/IEC 17025:2017 (A2LA-accredited calibration)
  • ITAR registered (DDTC)

FAQ

Common questions about Curtiss-Wright

Who owns Weed Instrument now?

Weed Instrument Co., founded in Round Rock, Texas, in 1968, is now part of Curtiss-Wright Corporation and operates as Curtiss-Wright Round Rock. Ultra Electronics acquired Weed in November 2008 and renamed it Ultra Electronics Nuclear Sensors & Process Instrumentation (NSPI). Curtiss-Wright agreed to acquire the Ultra Energy business in May 2024 for $200 million and completed the purchase on December 31, 2024.

Does Curtiss-Wright Round Rock still make aerospace RTDs?

Yes. The aerospace RTD line continues in Round Rock under an AS9100D quality system. The team winds its own platinum and nickel sensing elements, which allows non-standard resistance curves, and builds immersion, surface, air and cryogenic temperature sensors for commercial and military aircraft and reusable launch vehicles. The company is also an FAA PMA supplier of aerospace temperature sensors.

Which Curtiss-Wright Round Rock RTDs are qualified for Class 1E nuclear service?

Models including the N9001 wide-range thermowell RTD, N9004 fast-response RTD, N9339 flexible spring-loaded RTD, N9356 and the 612 series are qualified to IEEE 323 and IEEE 344 for Class 1E service. For European and EDF-design plants, the KN series is qualified to RCC-E. The company reports that its temperature sensors are used for reactor coolant monitoring in more than 80% of US reactors.

What replaces an obsolete Rosemount 1151 pressure transmitter in a nuclear plant?

For non-safety applications, the Curtiss-Wright DTC3 is a fully analog drop-in replacement that uses the same mounting bracket. For Class 1E safety-related service, including post-accident monitoring, the DTN2070 pressure transmitter is the qualified option. The N-E11 and N-E13 transmitters follow the Foxboro design and are LOCA tested. Plant engineers should confirm qualification documentation against their specific environmental and seismic requirements.

What are N9487 and N9488 fiber-optic converters used for?

The N9487 fiber-optic transmitter and N9488 receiver are nuclear-qualified analog converters that carry instrument signals over optical fiber. Because the fiber link is non-conductive, the pair provides electrical isolation between safety-related and non-safety systems. Companion FOT-CC and FOR-CC units handle contact-closure signals. For industrial networks, the EOTec 2000 and MX multiplexers carry Ethernet, analog and serial signals.

Who represents Curtiss-Wright Round Rock in the Southeast?

Vaughn Associates, Inc., an independent manufacturer's representative headquartered in Huntsville, Alabama, represents Curtiss-Wright Round Rock in all of its territories. Vaughn's engineers help aerospace, nuclear and industrial customers define sensor type, element, qualification and documentation requirements, coordinate quotes and technical questions with the Round Rock factory, and follow each order through delivery.

Your Curtiss-Wright sales engineers in the Southeast.

Coverage: All Vaughn Associates territories.

Request a quote

Get pricing and application help for Curtiss-Wright.

Share your requirements and a Vaughn sales engineer will coordinate with the factory on the right configuration and a quote.

We respond within one business day. We never share your information.