Leak & Flow Testing Equipment

Leak and flow testers that catch bad parts on the line, from medical tubing to EV battery packs.

What is leak testing equipment?

Leak testing equipment verifies that a sealed part, such as a housing, fluid circuit, medical device or battery pack, does not leak beyond a specified rate. Production leak testers use pressurized or evacuated air, measure the resulting pressure change or flow, and give a fast pass/fail result with data for traceability.

Flow testing is the counterpart. Instead of proving a part holds pressure, it confirms that intended passages such as orifices, nozzles, filters and tubing pass the right amount of flow. Many plants run both on the same instrument platform.

How leak and flow testing methods work

A typical air test cycle runs in four phases: fill the part to test pressure, stabilize while temperature and part stretch settle, measure, and exhaust. The measurement phase differs by method:

  • Absolute pressure decay: A transducer watches the isolated part’s pressure fall. Leak rate is calculated from pressure drop, internal volume and test time.
  • Differential pressure decay: A differential transducer compares the part with a leak-tight reference volume, resolving smaller changes at higher test pressures.
  • Mass flow: The part stays connected to regulated supply pressure, and a flow sensor measures make-up flow, which equals the leak rate.
  • Flow testing: Air flows through an intended path, and the tester checks that flow or pressure falls within limits.
  • Helium tracer gas: The part is charged with helium, and a mass spectrometer detects helium escaping in a vacuum chamber, accumulation chamber or at a sniffer probe.
Method What it measures Best for Limitation
Absolute pressure decay Pressure drop over time Small to medium volumes, simple setup Resolution falls at high pressure and large volume
Differential pressure decay Difference from reference volume Tighter limits on small and medium parts Needs matched reference volume
Mass flow Make-up flow at test pressure Large volumes such as battery packs and tanks Longer fill on big parts
Flow test Flow through intended path Orifices, nozzles, filters, tubing Not a leak test
Helium tracer Helium escaping the part Very low leak rates, hermetic parts Higher cost and cycle complexity

Physics sets the practical limits. By the gas law, a small temperature change in the part or test air changes pressure just like a leak does. That is why stabilization time, part temperature control and good fixture design matter as much as the instrument.

Common applications

  • Automotive and EV manufacturing: die-cast housings, cylinder heads, fuel and fluid circuits, battery packs, trays and cooling plates at plants across Alabama, Georgia, South Carolina and Tennessee.
  • Medical devices: tubing sets, connectors, bags and molded disposables in cleanroom assembly.
  • HVAC and appliances: refrigeration circuits and water-carrying components.
  • Hydraulics and gas components: valves, fittings and regulators.
  • Aerospace: fluid and pneumatic components.
  • Electronics: sealed enclosures with IP ratings.

Choosing the right leak testing equipment

The best leak test starts with a meaningful specification. “No leaks” is not testable, but a leak rate at a stated pressure is. From there, part volume and required sensitivity point to pressure decay, mass flow or helium, and cycle time narrows the choice further. Expect the fixture, seals and part temperature to decide whether the test is repeatable. Qualify the test with known good parts and calibrated leaks before production, then verify it daily.

Manufacturers we represent for leak testing

Tecna Marposs has built air leak and flow testers in Mirandola, Italy, since 1983 and has been part of the Marposs Group since 2016. Its Provaset T3L instruments cover absolute and differential pressure decay, flow and mass flow testing. The compact T2 and rugged 2SEAL suit bench stations, and TM3 modules bring up to sixteen channels to automated lines. LTC and Leak Master tools verify testers in production, and the wider Marposs group adds helium tracer gas systems and turnkey test machines, with US support from Marposs Corp. in Auburn Hills, Michigan.

Get local application support

Our engineers work with automotive, medical and industrial manufacturers on test method selection, fixture design and trials with Marposs. Visit engineering support, request a quote, or find your area manager on the territories page.

Product types

Types of Leak & Flow Testing Equipment we can help you specify.

01

Absolute pressure decay leak testers

The part is pressurized, isolated and stabilized, then the tester measures how much pressure falls over a timed interval. Tecna's Provaset T3LP bench instrument and compact T2 use this method for small and medium volumes.

02

Differential pressure decay leak testers

A differential transducer compares the test part against a sealed reference volume, resolving very small pressure changes even at high test pressure. The Provaset T3LD is Tecna's differential decay instrument.

03

Mass flow leak testers

Instead of watching pressure fall, a flow sensor measures the air needed to hold the part at test pressure, which stays sensitive on large volumes. Tecna's Provaset T3LMF works from vacuum to 6 bar with 0.01 cm³/min resolution for battery packs, cooling plates and tanks.

04

Flow testers

Flow testers confirm that orifices, channels, filters, nozzles and tubing pass the right flow, alongside or instead of leak checks. Tecna's T3LPF combines flow and leak testing, and the T3LPQ measures flow directly with a flow sensor.

05

Multi-channel leak test modules for automation

Headless measurement modules install inside assembly machines, rotary tables and multi-station cells. Tecna's TM3 modules run up to sixteen independent channels from one operator interface and can mix test methods.

06

Rugged compact leak testers

Shop-floor instruments built for heavy mechanical production, with simple touch interfaces and Ethernet and USB connectivity. Tecna's 2SEAL tests up to 6 bar with 1 Pa resolution.

07

Leak tester calibration and verification tools

Reference leaks and simulators confirm that a tester detects a known leak before or during production. Tecna's LTC installs in line and works with other brands' testers, and the Leak Master serves as a calibrated reference leak and pressure calibrator.

08

Helium tracer gas leak test systems

Helium systems detect far smaller leaks than air methods using vacuum chambers, accumulation chambers or sniffer probes. The wider Marposs group supplies helium test systems for battery cells, packs, trays and HVAC components.

Selection guide

How to choose Leak & Flow Testing Equipment

  1. 01

    Translate the product requirement into a leak rate at a defined pressure and temperature, such as cm³/min at test pressure, rather than a simple pass/fail pressure drop.

  2. 02

    Match the method to internal volume and required sensitivity: pressure decay for small and medium volumes, mass flow for large volumes, helium for very small leak rates.

  3. 03

    Budget cycle time realistically, including fill, stabilization, test and exhaust, since warm or flexible parts need longer stabilization.

  4. 04

    Design fixtures and seals with the tester; seal leaks, trapped volume and part movement are the most common sources of false rejects.

  5. 05

    Control temperature effects from washing, machining or molding, because a few degrees of change in part or air temperature can look like a leak.

  6. 06

    Plan integration with automation and traceability, including PLC I/O, Profinet or Modbus, barcode reading and result storage for SPC.

  7. 07

    Build in daily verification with a calibrated reference leak so you can prove the tester is detecting correctly.

Standards & regulations

  • ASTM E498 and E499 (helium mass spectrometer leak testing)
  • ASTM F2095 (pressure decay leak testing of flexible packages)
  • ISO 11607 (packaging integrity for terminally sterilized medical devices)
  • ISO 13485 (quality management for medical device manufacturing)
  • IEC 60529 ingress protection (IP) sealing requirements

Industries

FAQ

Leak & Flow Testing Equipment: frequently asked questions

What is the difference between pressure decay and mass flow leak testing?

Pressure decay fills a part, isolates it and measures how far pressure drops over time, then calculates leak rate from volume. It is simple and sensitive on small and medium volumes. Mass flow testing measures the air that must flow into the part to keep it at test pressure, which reads leak rate directly. Because it does not depend on detecting a tiny pressure change in a large volume, mass flow stays fast and sensitive on big parts.

What is the difference between absolute and differential pressure decay?

Absolute pressure decay measures the part's pressure with one transducer and looks for a drop, so resolution is limited when test pressure is high relative to the leak signal. Differential decay compares the part against a sealed reference volume with a differential transducer that only sees the difference, resolving much smaller changes. Differential testing also cancels some temperature effects when the reference and part experience similar conditions.

How do you calculate leak rate from a pressure decay test?

Leak rate equals the internal test volume multiplied by the pressure drop, divided by the test time. To express it as standard cubic centimeters per minute, use the volume in cubic centimeters and the pressure drop as a fraction of atmospheric pressure, then scale time to minutes. For example, a 100 cm³ part losing 10 Pa in 10 seconds leaks about 0.06 sccm. Temperature changes during the test distort this result.

When is helium leak testing necessary instead of air testing?

Air methods such as pressure decay and mass flow cover most production leak specifications, but their sensitivity is limited by temperature effects and cycle time. When a specification requires very small leak rates, such as refrigerant circuits, some battery cells or hermetic components, helium tracer gas testing with a mass spectrometer detector is used. Marposs offers helium vacuum chamber, accumulation and sniffing systems alongside Tecna air testers.

How can I verify a leak tester is working correctly on the production line?

Test a known master part and a calibrated reference leak at the start of each shift or at defined intervals, and record the results. Tecna's Leak Master provides a calibrated reference leak and pressure calibration. Its LTC (Leak Tester Control) installs between the tester and the part, simulates known leaks and confirms the instrument responds correctly, and it also works with other manufacturers' testers.

Who sells leak testing equipment in Alabama, South Carolina and the Southeast?

Vaughn Associates, Inc., headquartered in Huntsville, Alabama, represents Marposs Tecna leak and flow testing equipment across all of its territories, including the automotive and manufacturing corridors of Alabama, Georgia, South Carolina, Tennessee and North Carolina. Vaughn's area managers help evaluate test methods, fixtures and cycle times with Marposs. The Territories page lists your local contact.

Application help

Need help specifying Leak & Flow Testing Equipment?

Describe your application. A Vaughn sales engineer will recommend options from the manufacturers we represent and coordinate a quote.

We respond within one business day. We never share your information.